Skip to main content

Table 2 Best parameters for the three fitted patients

From: Phase-dependence of response curves to deep brain stimulation and their relationship: from essential tremor patient data to a Wilson–Cowan model

Parameter

Symbol

Best fit values

Patient 1

Patient 5

Patient 6

I to E weight

\(w_{IE}\)

9.4014

26.048

5.2064

E to I weight

\(w_{EI}\)

9.6306

25.3384

24.4813

E to E weight

\(w_{EE}\)

6.7541

1.548

2.7514

Sigmoid steepness parameter

β

1.1853

2.4234

4.1933

Time constant (s)

τ

0.0758

0.29984

0.2513

Constant input to E

\(\theta_{E}\)

1.4240

22.8621

2.9127

Constant input to I

\(\theta_{I}\)

−3.2345

−9.9279

−3.4008

Noise standard deviation

ζ

0.0457

0.013707

0.0263

Stimulation magnitude

δE

0.001684

0.00598

0.001686

Stimulation delay (ms)

\(\Delta t_{\text{stim}} \)

138.8366

444.1573

183.4711